“O-Cell” Osterberg equivalent pile tests

Bi-Directional Pile Load Tests

O-Cell (Osterberg) equivalent bi-directional static load tests up to 12000 t, with Albatech Testing Services LLP.

Overview

Bi-Directional Pile Load Tests at SRGPL

We have partnered with Albatech Testing Services LLP, a UAE-based testing services firm, which brings the expertise of “O-Cell” Osterberg-equivalent pile tests.

The BDSLT cell is a jack-like device installed sacrificially within the foundation element. It is specifically engineered to have negligible internal friction, even with eccentric movement. The cell's position within the foundation is set according to the test programme. A typical level is chosen where the capacity above and below the cell is equal, which maximises the load that can be mobilised during the test.

Bi-directional load cell assembly being lowered into a pile reinforcement cage
12000 tBi-directional test capacity
UAETechnology partner: Albatech

From the field